Custom Machines

Laser micromachining is an extremely versatile manufacturing process, and the General Purpose Micromachining Centre offers the ultimate flexibility in manufacturing, R&D, and job shop environments. This system is ideal marking, cutting, scribing, bending, welding, and drilling processes on almost any material, and is available with a wide range of laser options and motion accessories.

  • Ultimate flexibility – ideal for R&D
  • Up to 6-axes available
  • Marking, cutting, engraving, drilling, etc..
  • Customisable work holding solutions – tubes and flat materials
  • Fully CE compliant

Positioning system (*example 6-axis configuration)

AB axis
Axis type 2D Galvo scanner
Travel Range 50-200mm
Maximum travel speed 3000 mm/s
Accuracy up to ± 5μm
Repeatability up to ±1μm
Resolution 250nm
X axis
Travel X 200 mm
Maximum travel speed 300 mm/s
Maximum linear acceleration 5 m/s2 (no load)
Accuracy up to ± 6μm
Repeatability ±1μm
Resolution 500nm
U axis
Travel U ±360° Continuous
Maximum travel speed 600 RPM
Run-out <25µm
Accuracy ± 72.7µrad
Repeatability ± 29µrad
Resolution 0.873µrad
Y axis
Travel Y 200 mm
Maximum travel speed 300 mm/s
Maximum linear acceleration 35 m/s2 (no load)
Accuracy up to ± 6μm
Repeatability ±1μm
Resolution 500nm
Z axis
Travel Z 50 mm
Maximum travel speed 300 mm/s
Maximum linear acceleration 5 m/s2 (no load)
Accuracy up to ± 6μm
Repeatability ±1μm
Resolution 500nm

Optical

Spot size (optics and wavelength dependent) down to 10μm
Laser wavelength 1064 / 532 / 355nm

* see “Laser Options” for further details

 

Control

System control Industrial HMI with control PC running MS Windows OS, HD touch-screen display with user-friendly GUI, Aerotech A3200 Motion controller
Laser and motion synchronization Laser pulse synchronized output for constant velocity cutting producing optimum results

Software

Graphical User interface Process control, manual motion control, machine self-diagnostics, user login, on-screen vision system
Database interaction Interfacing with FDA approved databases via SQL (optional). User access control via login through MS Active Directory (optional).

Physical Characteristics

Dimensions (approx.), W×D×H 1300×1200×1700 mm
Power requirements, maximum 4500 W

(* Machine can be customised on request.)

Laser Wavelength Power Pulse duration Repetition rate Beam quality
Fiber laser 1070nm 50-300W Continuous Modulation up to 50kHz M2<1.05
ns laser 1064/532/355nm up to 50W <30 ns Single shot to 200kHz M2<1.3
ps laser 1064/532/355nm up to 50W <10 ps Single shot to 1MHz M2<1.5